INSPECTION, MEASURING AND OTHER EQUIPMENT

Cat. №

Description

Technical Data

11.1 Conductivity meter

111204

Conductivity meter Измервателни Range: 0,0 to 1999 μS/cm
Accuracy: 1 μS/cm
ATC

111205

Laboratory pH/conductivity meter
model 990
Измервателни
Range: 0.00 to 14.00 pH
0 to 2×10000 μS/cm
0 – ±1999 mV
0 – 100°C
Accuracy ± 0.01 pH
± 1% F S
± 0.1% F S
± 0.5°C
11.2 Laser apparatus

111206

Laser therapy apparatus

ИзмервателниPurpose: For medical therapy in:
Dentistry, gynaecology, dermatology, urology, neurology and others.

 


Range: 10 – 5000 Hz
Input power: 10 W
Wave length: 0.8 – 0.95 μm
Impulse continuance: 70 – 200 ns
Dimensions (ext):
320x280x135mm
Weight: 4.5kg

11.3 Luminometers

111288

Luminometer educational

Измервателни

Purpose: For chemical and biochemical analyze of liquids.

Input voltage: 220 V; 50 Hz
Spectral range: 220 to 450 nm
Detection limit (in molecules):
– hydrogen peroxide – 10 -6
– ATP – 10 -15
– peroxidase chrena – 10 -15
– luminal – 10 -9
Number of measured impulses for 1 sec.: 103 to 104 photons

11.4 Oxymeters 

iz-4

1112055

HI 9142 Oxygen range: 0,00 до 50,0 mg/l ± 1%
Temperature range: -5°С до 50°С ±0.2°С
Calibration: manual; АТС

1112056

HI 9146 Oxygen range: 0,00 до 45,0 mg/l ± 1,5%
Saturation range: 0 до 300% ± 1,5%
Temperature range: -5°С до 50°С ±0.2°С
Calibration: 1 or 2 points; АТС

1112057

HI 9147 Oxygen range: 0,00 до 19,9 mg/l ± 1,5%
Saturation range: 0 до 600% ± 1%
Temperature range: -5°С до 50°С ±0.2°С
Calibration: 1 or 2 points; АТС

11.5 Polarimeters

11.6 Chromatographs

1112096

Gas chromatograph
model 8610С

Измервателни

Features:
Chromatographic oven temperature programming and a temperature range of 400°C above the ambient;
Injector columns excluding contact of the sample with hot metal surfaces;
Electronic pressure control for all gases;
You set the pressure of the carrier gas;
Visualization on the display of any of the monitored zone, the status of the valve, a digital recording of the temperature, pressure and voltage;
Software PeakSimple:
Windows XP (compatible with Windows ‘98/2000/ME) based, built-in serial port interface for the collection, processing and storage of data;
RS 232 serial cable
Accessories:
Thermal Conductivity detector TCD
3’x1/8’’ S.S. Silica Gel Packed Column
Flame – ionization detector FID
Detailed, illustrated instructions for use

1112097

Liquid chromatograph 

By request

 

Измервателни

11.7 BUILDING MATERIALS TESTING EQUIPMENT

1112058

Measurement of the permeability of the cement 

1112059

Determining the consistency of the cement 

1112060

Determination of the tensile strength of the cement 

1112061

Determination of water permeability of concrete 

1112062

Determination of hardness of the concrete

1112063

Determining the pressure of the concrete 

1112064

Preparation and casting of samples

Измервателни

11.8 Penetrometers

for soil, bitumen, fruit, construction materials and others

Измервателни

11.9 Photometers and readers

11120101

Flame photometer

Измервателни

Range: 0-199,9 rpm
Sensitivity:
Na 3-10 ppm
K 3-10 ppm
Li 5 -100 ppm – option
Ba 100 – 200 ppm – option
Ca 5 – 100 ppm – option

Linearity: better then 2 %
Works with propane, butane, or natural gas
Compressor for dry air: 6 l/ min.

1112098

Biochemical photometer manual 
“Photometer M-2000”

Application:
Laboratories for analysis of water and food laboratories for quality control, clinical
biochemistry, hematology, E.I.A.

Измервателни

Range: 340 to 700 nm, through a filter with a step 10nm
Manual selection of 12 position filter disc
Automatic detection of filter
Filters: 340, 405, 505, 546, 630, with 7 optional positions
Real time Absorbance range 3.5 Od
photometric accuracy: better than 1% value of the absorption
Photometric accuracy: ±1 %
Lighting: Halogen
Square cuvette holder for 10 mm cuvettes
The holder has a Peltier element in order to maintain 37°C
Minimum volume of sample: 500 μl
L.C.D. display 2 lines with 20 symbols
Memory Capacity: 50 analytical methods
Computational abilities: Absorption, Endpoint, Fixed time, Kinetic, Differences Electrolytes
Internal calibration software
RS232C interface. With or without printer

1112099

Microplate reader
AT-838 (Рийдер)
Application:
Clinical diagnostic.Quality control of foods

Измервателни

 

Spectral range: 400 to 700 nm

Equipped with 450 nm and 600 nm filters (options choices 405, 490, 548 or 630 nm)
Measuring range: 0,000 to 2.500 OD

Photometric accuracy: ± 1% at 450 nm
Accuracy 1% c.v. at 450 nm
Stability: 0,005 OD deviation / hr

Light source: Halogen lamp 6 V/10 W
Interfaces: RS232 and CENTRONIC built-in printer
Response time: 60 sec. Poster, incl. print outcome
Power supply: 220 V ± 10% 50 Hz ± 1 Hz

11120100

Dishwasher for plates 

Измервателни

Memory: 50 programs

Wash cycle: from 1 to 103 modes

programmable volume: 50 to 400 μl

Equipped with a 2 – liter bottles
detergent, rinse and waste

Power supply: 220 V ± 10% 50 Hz ± 1 Hz

 

11.10 Colorimeters

Cat.

Description

Technical Data

11120104

HI 83200

kontrolni-01-ru

 Light blocking cuvette holder
Backlit LCD
BEPS (Battery Error Prevention System) Alerts users in the event a low battery could effect readings
PC compatible via USB
Powered by rechargeable batteries or 12 VDC
Save and recall logged data at the touch of a button.
On-screen tutorial; with the tutorial function enabled, short guides relating to current operation are displayed.
HELP button; screen specific help can viewed at the touch of a button.
Method selection; users can easily select parameters via the Method button.
Setup button; instrument preferences such as backlight intensity and screen contrast can be changed via the setup button.

 

11120105

Тintometer F

Измервателни

Measuring principle Visual, in terms of Lovibond® units
Modes Transmittance, reflectance
Range 0.1 – 79.9 Red, Yellow; 0.1 – 49.9 Blue;
0.1 – 3.9 Neutral
Resolution 0.1 Lovibond® unit
Optical system 11 glass-filled nylon racks containing a graduated range of Lovibond® colour glasses
Viewing system Fully adjustable, prismatic with integral blue filter for light standardisation
Light source 2 x 12 Volt, 10 Watt tungsten halogen lamp
Illuminant Approximates to daylight
Path length Up to 153 mm (6”)
Power pack 12 Volt ac, switchable to suit 220/110 Volt supply
Approvals CE
Instrument housing Fabricated sheet steel with a tough, textured paint finish
Dimensions Width 330 mm, depth 410 mm, height 230mm

11120106

Clormic

Измервателни

Wavelength range: 400 to 800 nm, by using special filters with a 40 nm band pass.

12 position Filter disc wheel selection .

Standard filters: 420, 440, 490, 520, 550, 580,

620, 680nm and 4 optionals.

Expanded Absorption range: -0.3 to 3.5 O.D.

in real time.

Transmission: 0 to 100 T %.

Photometric accuracy: >1 %.

Photometric precision: ±1 %.

Photometric stability: 0.004 A/hr.

Light source: Long life tungsten lamp.

Detector: Solid state.

Sample chamber: 10 mm cuvettes or test tubes

of 12 and 16 mm O.

Minimum volume: 1 ml.

Display: Alphanumeric LCD display of 2 lines

of 20 characters.

Calculation functions: Transmission T %. Absorbence, Concentration by factor or standard concentrations.

Calibration: Self adjusting by software.

RS-232 interface.

ON/ OFF switch.

Interactive LCD display.

Numeric and function keypad

11120107

WSD-3

Измервателни

– Measuring system: reflection

– Spectral range 400 to 700 nm

– Illumination standard: D 65

– Measuring time: 10 sec.

– Light source Halogen lamp: 6V 12W

– Head entrance diameter: 22 / 6 mm

– Field of vision 10?

– Reading precision: X,Y ± 0.0001, other scales ± 0.01

– Measuring error: 0.1

– Stability

– Zero set : 0.1

– Measuring error: 0.1

– VPower variation 0.1

– Measuring precision:0.1

– Preheat time: 10 min.

– Ambient conditions:0 – 40 ?C

– Power requirement: 220V 50Hz 10%